Correct operating environment of medical oil-free air compressor

Correct operating environment of medical oil-free air compressor

发布日期:2018-11-28 作者: 点击:

Correct operating environment of medical oil-free air compressor

1. Timely discharge the sewage in the gas storage tank, and it should be discharged at least once a week.

2, mute no oil air compressor itself does not contain any oily substances, do not add any lubricating oil and oily substances.

3, strictly in accordance with the air compressor calibrated voltage, frequency, rated load operation, the role will be better and safer.

4. Pay attention to daily protection. Correct use and protection, can extend the service life of air compressor, prevent or reduce the onset of the problem.

5, work not to use, to develop the habit of cutting off the power supply in time. When moving air compressor or connecting other equipment, it is necessary to cut off the power supply.

6. It must be operated within the pressure range set at the factory (generally, the maximum pressure set at the factory is 8bar and the pressure can be relieved safely at 8.8bar), otherwise there will be the risk of gas storage tank blasting. (for special pressure, please contact the manufacturer for customization).

7, pay attention to the power voltage and the air compressor nameplate logo. When the power supply voltage is higher than the applicable voltage of the air compressor, it may cause personal accidents and damage the air compressor. When the power supply voltage is lower than the applicable voltage of the air compressor, it will cause poor startup and even damage the motor.

8. Please regularly and properly check and replace the air inlet filter. Generally, check it once after 300 hours of operation. Adhere to the filter and cleaning can prevent most of the problems, not clean filter can reduce the function of the compressor and the service life of the compressor.

9. The filter should be cleaned in time according to the application situation, and the accessories and cables should be checked regularly. If damaged, the filter should be replaced immediately. Should adhere to the machine clean and dry oil, so as to give full play to its function. When the air compressor is not in use, the air in the gas tank should be released, and the sewage in the gas tank should be discharged, and stored in a boring environment.

10, the correct use of environment: air compressor normal use environment at 5 ℃ to 40 ℃, shall not be placed in a place without shade not in wet and dark local work, careful in store flammable and explosive liquid gas and dust, volatile gas workplaces. Keep the environment tidy and prevent unnecessary incidents.