Explosion-proof oil-free air compressor maintenance what are the skills?
1. Timely discharge the sewage in the gas storage tank, and it should be discharged at least once a week.
2, oil-free air compressor itself does not contain any oily substances, do not add any lubricating oil and oily substances.
3, strictly in accordance with the air compressor calibration voltage, frequency, additional load work, the role will be better and safer.
4. Pay attention to daily maintenance. Correct use and maintenance, can extend the service life of the air compressor, prevent or reduce the outbreak of problems.
5, work not to use, to develop the habit of cutting off the power supply in time. When moving air compressor or connecting with other equipment, the power supply must be cut off.
6. It must be operated within the pressure range set at the factory (generally, the maximum pressure set at the factory is 8bar and the pressure can be relieved safely at 8.8bar), otherwise there will be the risk of gas storage tank blasting. (for special pressure, please contact the manufacturer for customization).
7, pay attention to the power voltage and the air compressor nameplate logo. When the power supply voltage is higher than the applicable voltage of the air compressor, it may cause personal accident and damage the air compressor. When the power supply voltage is lower than the applicable voltage of the air compressor, it will cause poor startup and even damage the motor.
8. Please regularly and properly check and replace the air inlet filter. Generally, check it once after 300 hours of operation. Adhere to the filter and cleaning can prevent most of the problems, not clean filter can reduce the function of the compressor and the service life of the compressor.
9. The filter should be cleaned in time according to the application situation, and the accessories and cables should be checked regularly. If it is damaged, it should be replaced immediately. Should insist machine cleanness does not touch smeary, such ability give full play to its function. When the air compressor is not in use, the air in the gas tank should be released, and the sewage in the gas tank should be discharged, and stored in a boring environment.
10, the correct use of environment: air compressor normal use environment at 5 ℃ to 40 ℃, shall not be placed in a place without shade not in wet and dark local work, careful in store flammable and explosive liquid gas and dust, volatile gas workplaces. Insist on a clean environment to prevent unnecessary accidents.